The air leakage that Dana described would keep your roof dry, but would undermine its thermal effectiveness.

Most commercial roof assemblies Never hassle with the fluffy things. They only meet up with 100% of the R-worth requirements for that roof with rigid foam (either EPS or polyiso) and skip the batts completely. That's the way in which I advise that you commence.

It truly is Secure to convey that an present residence doesn't have fantastic roof ventilation if there are no soffit vents or ridge vents. It is also Protected to state that, even when there are actually soffit vents and ridge vents, the roof isn't ventilated if it consists of valleys, hips, dormers, or skylights.

We conduct a reverse business cellular phone lookup to discover documents matching the phone number data provided by the business.

Customer support was reminiscent of the previous times. They communicated as important concerning rain delays. Their employees mounted a wonderful, new roof, cleaned up right after them selves, and remaining my roses in exactly the same ailment since they have been right before they arrived.

You're proposing an uncommon method of insulating your roof. If I understand you correctly, you want to install EPS involving the tops within your roof trusses plus your roof sheathing.

Sure a cathedral ceiling element could well be really related however the obstacle of many a fantastic read cathedral ceilings will be the included structural things, electrical packing containers, and the will for wood board ceilings all which start compromising the drywall layer which in the element is applied in the air barrier.

So the query is: seal the stucco vents and incorporate the spray foam roof and Don't be concerned about condensation? You can find pretty little reduced-hanging fruit in our kind of development, In particular on existing residences, which is why folks are becoming sucked into the spray foam roof fraud.

Our cooler mornings could make the inside of my metal roof sheeting to sweat a bit given that it will be in touch with the warmer unvented fiberglass-insulated purlin "cavity" underneath. As soon as roofing company charlotte our incredibly hot Caribbean sunshine starts to kick in I need this dampness to dry and/or diffuse out of this cavity, with the gypsum sheeting, into the cathedral dwelling Area beneath, to then be blown outside of my 4x3 gable window. A vapor barrier would completely retard this process.

I suspect that Bill Rose is correct: every read what he said one of these failures require moisture that is carried by going air. They are not diffusion failures. If the rafter bays seriously are adequately dense-packed -- a giant if -- the chance of air motion is quite small.

A. As I wrote during the post, "Most rafters aren’t deep ample to accommodate the insulation required to meet up with least R-values necessary by code, especially if the rafter bays incorporate a air flow channel. ...

Builders resolve this issue by furring down or scabbing on more framing under the rafters to deepen the rafter bays.

Martin, I think your note re: 2009 IRC table R806.4, min impermeable insulation stages req'd for condensation Regulate in unvented roof assemblies for each climate zone, wants clarification; you said

Sorry, Martin, I now comprehend that "new design" does not necessarily signify "new residence to get constructed", and "an unvented attic, with R-50 under the roof" ought to have been "an unvented attic, with an R-50 roof'. Because It is really apparent to me doesn't signify It can be obvious to Anyone else.